Protection and Control for Submersible Pumps

                    

Setting Up Three Phase

Setting up Pumptron is easy: Turn POWER switch to ON, then press START/RESET button, this starts the pump for ten seconds priming time. During that period the yellow light turns ON: with a small screwdriver adjust the little  screw in SENSOR/ADJUST until the green light turns ON. The yellow light turns OFF and the green light remains ON. The pump is now detected and under protection.

Set the TIME SET knob to the desired water recovery time.

Pumptron will run the pump until the water is exhausted, then the timer takes over. After the pre selected time lapses the pump will start again. The sequence will repeat until the apparatus is turned OFF.

If the pump is overloaded, it will be stopped and PUMP OVERLOAD super red light will flash. Pressing START/RESET will restart the pump; if the condition persist it will stop instantly, otherwise the system will resume normal operation. Overload condition cancels out the ten seconds priming time.

If a level detecting devise is plugged in FLOAT SWITCH, Pumptron will stop once the desired level of water is reached and will restart when the level drops. The pump is then running fully automatic, protected and controlled.

     HOME    

Pumptron
111 Shepherds Hill

Harold Wood Romford Essex

RM3 0NP 

United Kingdom 

Last Updated

Monday, 08. August 2005

Phone:   0044 1708 371584

Mobile:  0044 7831 298116
Email:
info@pumptron.co.uk