Protection and Control for Submersible Pumps

                    

Pumptron must have been previously installed by a qualified electrician.

 

POWER: When power is turned ON, a self test occurs; the red light tuns ON and the SYSTEM STANDBY light flashes.

 

START/RESET: Press the yellow button; the yellow and green lights turn ON and after ten seconds the yellow light turns OFF and the green remains ON.

 

TIMER: The timer switch selects the scales of the TIME SET knob. The HOUR position sets the  3 HOURS inner scale and the DAY position the 24 HOURS scale. This sets the time required for the bore to refill with water.
 

Adjust the TIME SET knob to an appropriate time to allow the bore to refill with water.

HOW IT WORKS:

STARTING: After the yellow button has been pressed, the yellow light turns ON and the pump starts forcibly for ten seconds, during this time the sensor detects  the normal function and the green light turns ON. At the end of the ten seconds the yellow lamp goes OFF and the green light remains ON indicating that the pump is running under normal conditions.

NO WATER: When the bore runs out of water, the green light turns OFF and the TIMER begins to count the time for the bore to refill. Once the time lapses, the pump will be started automatically and it will run until the water again runs out.

At the right hand side of the picture above the Float Switch plug can be seen; when a float switch from a tank or dam, or a pressure switch is connected, Pumptron will run only when the switch is ON. This function will operate with any type of level or pressure switching device.

OVERLOAD: Many reasons can cause a pump to overload. (See "Experiences" in these pages) When an overload occurs, Pumptron stops the pump and the PUMP OVERLOAD super red light flashes. Press the reset button once; if the overload condition has disappeared, the system will resume normal function otherwise it will return instantly to the flashing overload light. If this is the case, call for service.

WARNING, never touch up the sensor adjust screw under any circumstances, doing so may cause the pump to run under abnormal conditions and may be irretrievably damaged.

 